ESTIMATEDWEBSITE.FR ≡ Pre-Owned Jewellery Mst Performance Game Tables & Game Room Furniture Airtec Motorsport
  • Our Products

  • 606212 ECRAS 200

606212 ECRAS 200

$38.43 $54.19
606212 ECRAS 200 3Ø Multimeter General Seven Segment Display ✔ LCD Screen – Language Support – Battery – Real Time Clock – Password Protection ✔ Current Transformer Ratio 1 – 5000 Voltage Transformer Ratio 1 – 5000 Demand Period 1-60 min. adjustable Connection Type 3F4T, 3F3T Measurements in Quadrants 4 Number of Measurements in a Period 256 LCD/Display Refresh Period 1 sec. Networks TT, TN, IT Phasor Diagram – Signal Waveforms – Min./Max./Demand Values ✔ Energy Measurement Number of Tariffs 1 Multi Sub-Tariffs (Peak, Day and Off-Peak) – 1Ø Phase Energy Meters ✔ 3Ø Phase Energy Meters ✔ 4 Quadrant Reactive Energy Meters – Current Measurement Input Measurement Range 10mA – 6A AC Overvoltage Category 300 V Cat II Measurement Surge Voltage 2 kV Power Consumption <0.2 VA Intermittent Overload 100 A for 1 sec. Sampling Frequency between 45-65 Hz 12.8 kHz Voltage Measurement Input Overvoltage Category 300 V Cat III Measured Range L-N 1-300 Vrms Measured Range L-L 2-500 Vrms Measured Frequency Range 45-65 Hz Power Consumption <0.1 VA Sampling Frequency between 45-65 Hz 12.8 kHz Power Quality Measurements Harmonics for Current and Voltage Phases Up to 31st THD – Voltage in % ✔ THD – Current in % ✔ Other Measurements Run Hour (Operating Time for Load in Hours) ✔ On Hour (Operating Time for Meter in Hours) Var✔ Int Counter (Number of Power Interruptions) ✔ According to IEC 61557-12 Total Active Power Class 0.5 Total Reactive Power Class 1 Total Apparent Power Class 0.5 Total Active Energy Class 0.5 Total Reactive Energy Class 2 Frequency Class 0.1 Current Class 0.5 Neutral Current Class 0.5 Voltage Class 0.2 Power Factor Class 0.5 THDV, THDI Class 1 According to IEC 62053-22 Total Active Energy Class 0.5S According to IEC 62053-23 Total Reactive Energy Class 2 Alarm Relay Outputs Number of Outputs – Type Max. Switching Current 10 A Max. Switching Voltage – Max. Switching Power – Digital Inputs Number of Inputs – Minimum Counting Frequency – Input Present or Not – Isolation Level – Digital Outputs Number of Outputs – Type – Switching Voltage Range – Minimum Switching Frequency – Isolation Level – Analog Outputs Number of Outputs – Range of Outputs 0-5 V, 0-10 V, -5-5 V, -10-10V, 0-20 mA, 4-20 mA – Isolation – Voltage AC 85-300V DC 85-300V Consumption AC <6VA DC <3W Supply Frequency 45-65Hz Min./Max./Avg. Values Hourly Records Daily Records Monthly Records Data Logging with timestamp Demand Alarm Records – Communication Protocol Modbus RTU Baud Rate 1200-57600 bps adjustable Parity Number Odd, Even, None Stop Bit 1 Address 1-247 Isolation 2750V RMS Mechanical Properties Weight (g) 296 g Protection Class Front IP40 / Rear IP20 Mounting Type Panel Mount Supply, Voltage, Current, Relay Outputs Stranded: 2.5mm² – 14AWG Solid: 4mm² – 12AWG, 2×1.5mm² – 2x16AWG Digital I/O, RS 485, Analog Output Stranded: 1.5mm² – 16AWG Solid: 1.5mm² – 16AWG, 2×0.75mm² – 2x18AWG Ambient Conditions Operating Temperature -20°C 70°C Storing Temperature -30°C 80°C Relative Humidity (No Condensation) Max. 95% EMC-EMI 300 VAC CAT II according to IEC 61010-1 ✔ EN 55011/A1:2010, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN61000-4-11 ✔ Schematics Network Connections Digital I/O and Alarm Output Connections 3 wires with 3CTs 4 wires with 3CTs 3 wires with 2CTsNOTE: CTs can be connected any phase. They are connected to phase 1 and phase 3 in this figure. Single Phase with 1CTNORE: CT and VT can be connected any phase. They are connected to phase 1 in this figure. Digital Output Connection Digital Input Connection Alarm Output Connection Analog Output Connection
Our Products

Our Products

  • 606212 ECRAS 200
    $38.43 $54.19
  • City 500 PMU
    $72.1 $118.24

© 2026 - ESTIMATEDWEBSITE.FR